Main menu

SPROTTE spinal needle on a sterile instrument table

Regional Anesthesia · Spinal

The original pencil-point spinal needle.

Ogival tip for atraumatic spinal anesthesia. Developed further with practitioners since 1979.

  • LUER
  • NRFit®
  • Made in Germany
Regional Anesthesia All products Request free samples
First SPROTTE® needle, developed with Prof. Dr. Sprotte
1979
Needle gauges in the range
22G – 27G
Needle lengths, from pediatric to obese patients
35 – 150 mm
Connector options, NRFit® to ISO 80369-6
LUER & NRFit®

SPROTTE®

Pencil-point. Displaces, does not cut.

SPROTTE® is the original pencil-point spinal needle for atraumatic spinal anesthesia. Developed in 1979 with Prof. Dr. Sprotte, and refined with practitioners ever since.

  • Spinal Anesthesia
  • 22G – 27G
  • 35 – 150 mm
  • LUER
  • NRFit®
  • With & without introducer

The tip in detail

  1. Ogival tip. Displaces instead of cutting.

    The closed tip displaces tissue during puncture, compared with the cutting Quincke tip.11–15

  2. Large lateral eye. Burr-free.

    Rounded edges, faster CSF backflow and good distribution of the local anesthetic.16

  3. Precision-ground stylet. Sealed exactly.

    Closes the lateral eye, stabilizes the needle and prevents tissue from being carried in.10

Real People. Real Care.

Born in dialogue with the clinic.

In the 1970s, spinal anesthesia was considered problematic because of complications such as post-dural puncture headache (PDPH). Prof. Dr. Sprotte and the brothers Horst and Heinrich Pajunk set out to develop a needle that would injure nerves, dura and vessels as little as possible.

Clinical experience and medical engineering know-how produced a needle with its own tip geometry in 1979. Numerous studies have since reported a lower PDPH incidence compared with conventional cutting needles.

Drawing of the SPROTTE needle from the patent of 10 December 1981
From the patent specification,
  1. 1970s

    Spinal anesthesia with a high risk of complications, including PDPH

  2. 1979

    First SPROTTE® needle, developed jointly by Prof. Dr. Sprotte and the Pajunk brothers

  3. 1987

    Publication of the “atraumatic universal needle” in Regional-Anaesthesie

  4. Today

    Range with LUER and NRFit® connectors, with and without introducer

Gloved hand opening the sterile pack of a SPROTTE needle

Made for everyday
work in the OR.

Features & benefits

What makes the SPROTTE® special.

Nine features that set the needle apart in daily use.

Key feature

Ogival tip

  • Atraumatic tip geometry
  • Studies show a lower PDPH incidence

Sources 11–15

Large lateral eye

  • Burr-free opening with rounded edges
  • Faster CSF backflow than with a cutting needle
  • Good distribution of the local anesthetic

Source 16 · 27G Quincke vs. 25G SPROTTE®

Stainless steel needle

  • Precisely machined, burr-free surface
  • Optimized for gliding and CSF backflow

Precision-ground metal stylet

  • Closes the lateral eye exactly
  • Stabilizes the needle
  • Prevents tissue particles from being carried in

Source 10

Color-coded stylet

  • Needle size visible and verifiable at a glance

Introducer with facet tip

  • Diameter matched to the spinal needle, length selectable
  • Short hub: little loss of working length
  • Conical hub protects the needle tip

LUER & NRFit®

Magnifying hub

  • Available on LUER and NRFit® needles

LUER

Standard hub

  • Available on LUER needles

Broad range

  • Many gauges and lengths
  • From pediatric to obese patients

Evidence

Backed by the literature.

Systematic reviews and comparative studies on tip design and PDPH, with all sources listed.

Comparison: atraumatic SPROTTE needle and cutting Quincke needle
SPROTTE® (atraumatic) compared with the Quincke needle (cutting) · graphic in German
Selected sources
  1. Arevalo-Rodriguez I. et al. (2017). Needle gauge and tip designs for preventing post-dural puncture headache (PDPH). Cochrane Database of Systematic Reviews.
  2. Nath S. et al. (2017). Atraumatic versus conventional lumbar puncture needles: a systematic review and meta-analysis. The Lancet.
  3. Atashkhoei S. et al. (2022). Sprotte versus Quincke spinal needles in cesarean section spinal anesthesia. Evidence Based Care Journal.
  4. Saenghirunvattana R. et al. (2008). A comparison study between newly-designed pencil-point and cutting needles in spinal anesthesia. J Med Assoc Thai.
  5. Sprotte G. et al. (1987). Eine „atraumatische“ Universalkanüle für einzeitige Regionalanästhesien. Regional-Anaesthesie.
Show all 17 sources
  1. Santos et al. (2023). Early vs. late sphenopalatine ganglion block in post-dural puncture headache.
  2. Sprotte G. (1997). Presentation on the SPROTTE® needle. ESRA.
  3. Atashkhoei S. et al. (2022). Sprotte versus Quincke spinal needles in cesarean section spinal anesthesia. Evidence Based Care Journal.
  4. Arevalo-Rodriguez I. et al. (2017). Needle gauge and tip designs for preventing post-dural puncture headache (PDPH). Cochrane Database of Systematic Reviews.
  5. Nath S. et al. (2017). Atraumatic versus conventional lumbar puncture needles: a systematic review and meta-analysis. The Lancet.
  6. Sprotte G. et al. (1987). Eine „atraumatische“ Universalkanüle für einzeitige Regionalanästhesien. Regional-Anaesthesie.
  7. Strupp M., Katsarava Z. (2009). Postpunktionelles Syndrom und spontanes Liquorunterdrucksyndrom.
  8. Cognat E. et al. (2021). Preventing post-lumbar puncture headache. Annals of Emergency Medicine.
  9. Chin K. J., Van Zundert A. (2023). Spinal anesthesia. NYSORA.
  10. Chin K. J., Van Zundert A. (2023). Spinal anesthesia. NYSORA (stylet / tissue particles).
  11. Atashkhoei S. et al. (2022). See source 3 (PDPH reduction).
  12. Segal S., Kodali B. S. (2023). Anesthesia for cesarean delivery. Springer.
  13. Arevalo-Rodriguez I. et al. (2017). See source 4 (tip design).
  14. Nath S. et al. (2017). See source 5 (atraumatic needles).
  15. American Society of Anesthesiologists (2016). Practice guidelines for obstetric anesthesia.
  16. Saenghirunvattana R. et al. (2008). A comparison study between newly-designed pencil-point and cutting needles in spinal anesthesia. J Med Assoc Thai.
  17. Saenghirunvattana R. et al. (2008). See source 16 (lateral eye).

Short form based on the current product page; add full bibliographic details before go-live.

Information for healthcare professionals. Statements on study results to be legally reviewed before publication.

Ordering information

Find the right article.

Filter by variant, gauge and connector. Articles go into your request list and are sent to customer service in one go.

SPROTTE® – Needles
Item description LUER item no. NRFit® item no. Unit
27G x 35 mm (1 1/3") with magnifying hub 111151-27A not available 25
27G x 123 mm (4 4/5") with magnifying hub 231151-27A not available 10
25G x 35 mm (1 1/3") standard hub, NRFit® with magnifying hub 001151-29E 001163-29E 25
25G x 90 mm (3 1/2") with standard hub 501151-29A not available 25
25G x 120 mm (4 3/4") with standard hub 031151-29A not available 10
25G x 123 mm (4 4/5") with standard hub 151151-29A not available 10
24G x 35 mm (1 1/3") with standard hub 001151-30E 001163-30E 25
24G x 120 mm (4 3/4") with standard hub 031151-30A not available 10
22G x 50 mm (2") with standard hub 071151-30C 071163-30C 25
22G x 120 mm (4 3/4") with standard hub 031151-30C not available 10

NRFit® is a registered trademark of GEDSA and is used with their permission.

Next step

Try SPROTTE® in your clinic.

Free samples via your local PAJUNK representative, delivered to your clinic.

Request samples
Anesthesiologist holding a SPROTTE needle in the OR